PingGateway 2024.6

CircuitBreakerFilter

Monitors failures. When the number of failures reaches a configured failure threshold, the circuit breaker trips, and the circuit is considered open. Calls to downstream filters are stopped, and a runtime exception is returned.

After a configured delay, the circuit breaker is reset, and is the circuit considered closed. Calls to downstream filters are restored.

Usage

{
  "name": string,
  "type": "CircuitBreakerFilter",
  "config": {
    "maxFailures":  configuration expression<integer>,
    "openDuration": configuration expression<duration>,
    "openHandler": Handler reference,
    "slidingCounter": object,
    "executor":  ScheduledExecutorService reference
  }
}

Properties

"maxFailures": configuration expression<number>, required

The maximum number of failed requests allowed in the window given by size, before the circuit breaker trips. The value must be greater than zero.

"openDuration": configuration expression<duration>, required

The duration for which the circuit stays open after the circuit breaker trips. The executor schedules the circuit to be closed after this duration.

"openHandler": Handler reference, optional

The Handler to call when the circuit is open.

Default: A handler that throws a RuntimeException with a "circuit-breaker open" message.

"slidingCounter": object, optional

A sliding window error counter. The circuit breaker trips when the number of failed requests in the number of requests given by size reaches maxFailures.

The following image illustrates how the sliding window counts failed requests:

Example sliding window error counter.
{
  "slidingCounter":  {
    "size": configuration expression<number>
  }
}
"size": configuration expression<number>, required

The size of the sliding window in which to count errors.

The value of size must be greater than zero, and greater than the value of maxFailures, otherwise an exception is thrown.

"executor": ScheduledExecutorService reference, optional

A ScheduledExecutorService to schedule closure of the circuit after the duration given by openDuration.

Default: The default ScheduledExecutorService in the heap

Example

In the following example, the circuit breaker opens after 11 failures in the previous 100 requests, throwing a runtime exception with a "circuit-breaker open" message. The default ScheduledExecutorService in the heap closes the circuit-breaker after 10 seconds.

{
  "type": "CircuitBreakerFilter",
  "config": {
    "maxFailures": 10,
    "openDuration": "10 seconds",
    "openHandler": {
      "type": "StaticResponseHandler",
      "config": {
        "status": 500,
        "headers": {
          "Content-Type": [ "text/plain" ]
        },
        "entity": "Too many failures; circuit opened to protect downstream services."
      }
    },
    "slidingCounter": {
      "size": 100
    }
  }
}
Copyright © 2010-2024 ForgeRock, all rights reserved.